24 known vulnerabilities in Siemens SCALANCE S615 Firmware (Siemens), 0 of them actively exploited (CISA KEV).
Key figures
24
Vulnerabilities
0
Actively exploited (KEV)
0
Used by ransomware
3
Critical
Vulnerabilities
Actively exploited vulnerabilities (CISA KEV) first, then by priority. Click a column header to re-sort the table.
| Critical | CVE-2017-14491 | thekelleys dnsmasq: Heap-Based Buffer Overflow | 9.8 | |
| High | CVE-2018-5391 | Linux Kernel: Uncontrolled Resource Consumption | 7.5 | |
| Medium | CVE-2021-3449 | NULL pointer deref in signature_algorithms processing | 5.9 | |
| Critical | CVE-2022-36323 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Injection | 9.1 | |
| High | CVE-2020-28400 | Siemens Development/Evaluation Kits for PROFINET IO: Allocation of Resources Without Limits or Throttling | 7.5 | |
| Low | CVE-2021-22924 | Https://github.com/curl/curl: Improper Input Validation | 3.7 | |
| High | CVE-2022-36324 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Allocation of Resources Without Limits or Throttling | 7.5 | |
| High | CVE-2022-31766 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Improper Input Validation | 8.6 | |
| High | CVE-2019-13946 | Siemens Development/Evaluation Kits for PROFINET IO: Uncontrolled Resource Consumption | 7.5 | |
| Critical | CVE-2024-50557 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Improper Input Validation | 7.2 | |
| High | CVE-2021-25676 | Siemens RUGGEDCOM RM1224: Improper Restriction of Excessive Authentication Attempts | 7.5 | |
| High | CVE-2021-25667 | Siemens RUGGEDCOM RM1224: Stack-based Buffer Overflow | 8.8 | |
| High | CVE-2024-50572 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Injection | 7.2 | |
| High | CVE-2017-2680 | Siemens Development/Evaluation Kits for PROFINET IO: Uncontrolled Resource Consumption | 6.5 | |
| Medium | CVE-2016-7090 | Siemens SCALANCE M-800 Firmware: security vulnerability | 4.0 | |
| Medium | CVE-2022-36325 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) | 6.8 | |
| High | CVE-2017-2681 | Siemens Development/Evaluation Kits for PROFINET IO: Uncontrolled Resource Consumption | 6.5 | |
| Medium | CVE-2022-46143 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Improper Validation of Specified Quantity in Input | 2.7 | |
| High | CVE-2022-46140 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Use of a Broken or Risky Cryptographic Algorithm | 6.5 | |
| Medium | CVE-2024-50558 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Improper Access Control | 4.3 | |
| Medium | CVE-2024-50561 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Cross-site Scripting | 4.3 | |
| Medium | CVE-2024-50559 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Path Traversal | 4.3 | |
| Medium | CVE-2022-46142 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Storing Passwords in a Recoverable Format | 5.7 | |
| Medium | CVE-2024-50560 | Siemens RUGGEDCOM RM1224 LTE(4G) EU: Improper Input Validation | 3.1 |