Product by Hitachi Energy

    Rtu500

    24 known vulnerabilities in Rtu500 (Hitachi Energy), 0 of them actively exploited (CISA KEV).

    Key figures

    24

    Vulnerabilities

    0

    Actively exploited (KEV)

    0

    Used by ransomware

    5

    Critical

    Vulnerabilities

    Actively exploited vulnerabilities (CISA KEV) first, then by priority. Click a column header to re-sort the table.

    Vulnerabilities in Rtu500 (Hitachi Energy)
    CriticalCVE-2010-2965

    Wind River VxWorks: security vulnerability

    also in 2 other products

    9.8
    HighCVE-2025-59375

    libexpat Project libexpat: Allocation of Resources Without Limits or Throttling

    also in 23 other products

    7.5
    HighCVE-2024-8176

    Libexpat: expat: improper restriction of xml entity expansion depth in libexpat

    also in 37 other products

    7.5
    CriticalCVE-2026-9079

    stale proxy password leak

    also in 4 other products

    9.8
    CriticalCVE-2026-8066

    Hitachi Energy RTU500 series CMU firmware: Relative Path Traversal

    also in 1 other product

    9.1
    CriticalCVE-2026-8065

    Hitachi Energy RTU500 series CMU firmware: Missing Authentication for Critical Function

    also in 1 other product

    9.1
    CriticalCVE-2026-6653

    libxml2: Use after free in xmlParseInternalSubset via improper entity resolution handling

    also in 5 other products

    9.8
    Not ratedCVE-2014-9195

    Phoenix Contact Software ProConOs and MultiProg Missing Authentication for Critical Function

    also in 1 other product

    —
    HighCVE-2026-6732

    Libxml2: libxml2: denial of service via crafted xsd-validated document

    also in 17 other products

    7.5
    HighCVE-2026-28388

    NULL Pointer Dereference When Processing a Delta CRL

    also in 3 other products

    5.9
    MediumCVE-2026-11856

    cross-origin Digest auth state leak

    also in 3 other products

    5.3
    HighCVE-2026-8932

    incomplete mTLS config matching in conn reuse

    also in 3 other products

    7.5
    HighCVE-2022-3353

    IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products

    also in 11 other products

    5.9
    MediumCVE-2026-8067

    Hitachi Energy RTU500 series CMU firmware: Missing Authorization

    also in 1 other product

    6.5
    MediumCVE-2026-17539

    Hitachi Energy RTU500 series CMU firmware: NULL Pointer Dereference

    also in 1 other product

    5.9
    HighCVE-2024-12169

    Hitachi Energy RTU500: security vulnerability

    6.5
    MediumCVE-2026-8927

    env-set cross-proxy Digest auth state leak

    also in 4 other products

    5.3
    HighCVE-2026-6276

    stale custom cookie host causes cookie leak

    also in 4 other products

    7.5
    HighCVE-2025-1445

    Hitachi Energy RTU500: Missing Synchronization

    7.5
    HighCVE-2023-46143

    Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC

    also in 18 other products

    7.5
    MediumCVE-2024-11499

    Hitachi Energy RTU500: NULL Pointer Dereference

    4.9
    MediumCVE-2024-10037

    Hitachi Energy RTU500: NULL Pointer Dereference

    4.4
    MediumCVE-2023-5767

    Hitachi Energy RTU500: Cross-Site Scripting (XSS)

    also in 4 other products

    6.0
    MediumCVE-2023-5769

    Hitachi Energy RTU500: Cross-Site Scripting (XSS)

    also in 4 other products

    5.4

    All products by Hitachi Energy