Siemens Development/Evaluation Kits for PROFINET IO: Uncontrolled Resource Consumption (CVE-2017-12741)
Published Sources: CVE.org
What is affected, what to do
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
The available sources name no fixed version. Check the vendor guidance in the references below.
- Affected
- Siemens Development/Evaluation Kits for PROFINET IO
eq All versions < V4.1.1 Patch 05..All versions < V4.1.1 Patch 05 - Siemens Development/Evaluation Kits for PROFINET IO
eq All versions < V4.5..All versions < V4.5 - Siemens SIMATIC Compact Field Unit
eq All versions..All versions - Siemens SIMATIC ET 200M (incl. SIPLUS variants)
eq All versions..All versions - Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)
eq All versions < V1.1.0..All versions < V1.1.0 - Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12
eq All versions..All versions - Siemens SIMATIC ET200ecoPN
eq All versions..All versions - Siemens SIMATIC ET200S (incl. SIPLUS variants)
eq All versions..All versions - Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)
eq All versions < V4.2.0..All versions < V4.2.0 - Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
eq All versions < V4.2.3..All versions < V4.2.3 - Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
eq All versions < V2.0..All versions < V2.0 - Siemens SIMATIC S7-1500 Software Controller
eq All versions < V2.0..All versions < V2.0 - Siemens SIMATIC S7-200 SMART
eq All versions < V2.03.01..All versions < V2.03.01 - Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)
eq All versions < V8.2.1..All versions < V8.2.1 - Siemens SIMATIC WinAC RTX 2010
eq All versions < V2010 SP3..All versions < V2010 SP3 - Siemens SIMATIC WinAC RTX F 2010
eq All versions < V2010 SP3..All versions < V2010 SP3 - Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants)
eq All versions < V2.1.1..All versions < V2.1.1 - Siemens SIMOTION C
eq All versions < V5.1 HF1..All versions < V5.1 HF1 - Siemens SIMOTION D
eq All versions < V5.1 HF1..All versions < V5.1 HF1 - Siemens SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)
eq All versions < V4.4 HF26..All versions < V4.4 HF26 - Siemens SIMOTION P V4.4 and V4.5
eq All versions < V4.5 HF5..All versions < V4.5 HF5 - Siemens SIMOTION P V5
eq All versions < V5.1 HF1..All versions < V5.1 HF1 - Siemens SINAMICS DCM w. PN
eq All versions < V1.4 SP1 HF6..All versions < V1.4 SP1 HF6 - Siemens SINAMICS DCP w. PN
eq All versions < V1.2 HF2..All versions < V1.2 HF2 - Siemens SINAMICS G110M w. PN
eq All versions < V4.7 SP9 HF1..All versions < V4.7 SP9 HF1 - Siemens SINAMICS G120 (C/P/D) w. PN (incl. SIPLUS variants)
eq All versions < V4.7 SP9 HF1..All versions < V4.7 SP9 HF1 - Siemens SINAMICS G130 V4.7 w. PN
eq All versions < V4.7 HF29..All versions < V4.7 HF29 - Siemens SINAMICS G130 V4.8 w. PN
eq All versions < V4.8 HF4..All versions < V4.8 HF4 - Siemens SINAMICS G150 V4.7 w. PN
eq All versions < V4.7 HF29..All versions < V4.7 HF29 - Siemens SINAMICS G150 V4.8 w. PN
eq All versions < V4.8 HF4..All versions < V4.8 HF4 - Siemens SINAMICS GH150 V4.7 w. PROFINET
eq All versions < V4.7 SP5 HF7..All versions < V4.7 SP5 HF7 - Siemens SINAMICS GL150 V4.7 w. PROFINET
eq All versions < V4.8 SP2..All versions < V4.8 SP2 - Siemens SINAMICS GM150 V4.7 w. PROFINET
eq All versions < V4.7 HF31..All versions < V4.7 HF31 - Siemens SINAMICS S110 w. PN
eq All versions < V4.4 SP3 HF6..All versions < V4.4 SP3 HF6 - Siemens SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)
eq All versions < V4.7..All versions < V4.7 - Siemens SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)
eq All versions..All versions - Siemens SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)
eq All versions < V4.7 HF29..All versions < V4.7 HF29 - Siemens SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)
eq All versions < V4.8 HF5..All versions < V4.8 HF5 - Siemens SINAMICS S150 V4.7 w. PN
eq All versions < V4.7 HF29..All versions < V4.7 HF29 - Siemens SINAMICS S150 V4.8 w. PN
eq All versions < V4.8 HF4..All versions < V4.8 HF4 - Siemens SINAMICS SL150 V4.7.0 w. PROFINET
eq All versions < V4.7 HF30..All versions < V4.7 HF30 - Siemens SINAMICS SL150 V4.7.4 w. PROFINET
eq All versions < V4.8 SP2..All versions < V4.8 SP2 - Siemens SINAMICS SL150 V4.7.5 w. PROFINET
eq All versions < V4.8 SP2..All versions < V4.8 SP2 - Siemens SINAMICS SM120 V4.7 w. PROFINET
eq All versions < V4.8 SP2..All versions < V4.8 SP2 - Siemens SINAMICS V90 w. PN
eq All versions < V1.02..All versions < V1.02 - Siemens SINUMERIK 840D sl
eq All versions < V4.8 SP3..All versions < V4.8 SP3 - Siemens SIRIUS Soft Starter 3RW44 PN
eq All versions..All versions
- Siemens Development/Evaluation Kits for PROFINET IO
Not sure whether and how you are affected? Ask a question about this vulnerability
Metrics
8.7
Priority
XIEM Effective CVSS: highest available CVSS rating from NVD and vendor data.
Source: Vendor (CNA), CVSS v4
7.5
CVSS v3
Severity High on the scale from 0 to 10.
Source: CVE.org
3.3 %
EPSS score
Moderate — model estimates 1-10% exploitation likelihood.
Source: FIRST EPSS, percentile 88.5
Show all metrics
- Severity
- High
Priority (0–325)
The priority score is a consolidated metric that condenses several individual signals into a single, action-guiding ranking: technical severity (CVSS), exploitation likelihood (EPSS), known-exploited status (KEV) and the context of the affected asset. The aim is to answer the only truly important question in vulnerability management: what first?
Read in glossary- 106.21 Methodology
Exploit maturity
An exploit is code or a technique that specifically uses a concrete vulnerability to force unintended behaviour — such as executing code or escalating privileges. It is the tool that turns a theoretical flaw into a practical attack.
Read in glossary- no public PoC known
XIEM Effective CVSS
XIEM® is the tiered managed-security operating model from NEOSEC and a registered trademark of NEOSEC GmbH. It extends classic SIEM — the central collection, normalisation and correlation of security-relevant events — with endpoint forensics, network visibility and deception technology, and consolidates them into three building tiers: Sentry, Orchestrate and Command.
Read in glossary- 8.7 Methodology
CVSS v3
CVSS is the globally established, open standard for assessing the technical severity of a vulnerability on a scale from 0 to 10. It describes how easily a flaw can be exploited and what damage it can cause — but not how likely its actual exploitation is. CVSS and the complementary EPSS deliberately answer different questions.
Read in glossary- 7.5
CVSS v4
CVSS is the globally established, open standard for assessing the technical severity of a vulnerability on a scale from 0 to 10. It describes how easily a flaw can be exploited and what damage it can cause — but not how likely its actual exploitation is. CVSS and the complementary EPSS deliberately answer different questions.
Read in glossary- 8.7
EPSS score
The EPSS score is the absolute model output for an individual vulnerability: the estimated probability of real-world exploitation within the next 30 days, expressed as a value between 0 and 1 (i.e. 0 % to 100 %). A score of 0.42 means „the model estimates a 42 % chance of real-world exploitation within 30 days“.
Read in glossary- 3.3 %
- Moderate — model estimates 1-10% exploitation likelihood.
EPSS percentile
The EPSS percentile is the relative position of a vulnerability within all EPSS-scored CVEs, expressed as a value between 0 and 1. A percentile of 0.90 means „this CVE has a higher EPSS score than 90 % of all other scored CVEs“. Unlike the EPSS score, it is not a probability — but a positioning within a ranking.
Read in glossary- 88.5
- Critical — this CVE ranks in the top fifth of all CVEs scored today (rank ≥ 80%).
KEV status
The KEV catalogue is a list maintained by the US authority CISA of vulnerabilities for which active exploitation in the wild has been confirmed. It answers not the question „how severe?“ but „is it already being attacked?“ — thereby sharply prioritising patching.
Read in glossary- —
- Published
CWE
CWE is a catalogue of typical weakness types in software and hardware — such as flawed input validation, unsafe memory handling or poor authentication. Where a CVE names a concrete vulnerability in a concrete product, a CWE describes the underlying class of defect.
Read in glossary- CWE-400
Detection rules
No NEOSEC detection rule is available for this vulnerability yet.
Classification under NIS2 and CRA
Rule-based classification from exploitation status and severity. It does not replace a case-by-case assessment.
NIS2
NIS2 is EU Directive (EU) 2022/2555 to raise the level of cybersecurity across the Union. It substantially broadens obligations compared with the first NIS directive: more sectors, mandatory risk management, staged reporting duties and personal accountability of senior management.
Read in glossary- High technical severity: assess and remediate the vulnerability in vulnerability handling under Art. 21(2)(e) NIS2 and document the decision.
CRA
The CRA is EU Regulation (EU) 2024/2847 setting horizontal cybersecurity requirements for „products with digital elements“ — from industrial controllers and software to connected consumer devices. For the first time manufacturers must ensure security across the entire product lifecycle, handle vulnerabilities and provide security updates.
Read in glossary- From 11.12.2027, Annex I Part II CRA requires manufacturers of affected products with digital elements to handle vulnerabilities without delay and provide security updates.
ISO/IEC 27001
ISO/IEC 27001 is the internationally leading standard for an information security management system (ISMS). It describes a risk-based, process-oriented framework to systematically plan, implement, review and improve information security.
Read in glossary- Control A.8.8, management of technical vulnerabilities: assess relevance to your systems, plan remediation and keep evidence.
Description
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
Source: cvelistv5, NVD (NIST)
Affected products
The following versions are affected. Older releases of the same product line are also vulnerable unless stated otherwise.
| Affected versions | Fixed in | ||
|---|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
|
|
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 |
|
|
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P |
|
|
| Siemens | SIMATIC Compact Field Unit |
|
|
| Siemens | SIMATIC ET 200AL IM 157-1 PN |
|
|
| Siemens | SIMATIC ET 200M (incl. SIPLUS variants) |
|
|
| Siemens | SIMATIC ET 200MP IM 155-5 PN BA |
|
|
| Siemens | SIMATIC ET 200MP IM 155-5 PN HF |
|
|
| Siemens | SIMATIC ET 200MP IM 155-5 PN ST |
|
|
| Siemens | SIMATIC ET 200pro IM 154-3 PN HF |
|
|
| Siemens | SIMATIC ET 200pro IM 154-4 PN HF |
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN BA |
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) |
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN HF |
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN HS |
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST |
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST BA |
|
|
| Siemens | SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 4AO U/I 4xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 |
|
|
| Siemens | SIMATIC ET200ecoPN: IO-Link Master |
|
|
| Siemens | SIMATIC ET200S (incl. SIPLUS variants) |
|
|
| Siemens | SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) |
|
|
| Siemens | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) |
|
|
| Siemens | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) |
|
|
| Siemens | SIMATIC S7-1500 Software Controller |
|
|
| Siemens | SIMATIC S7-200 SMART |
|
|
| Siemens | SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) |
|
|
| Siemens | SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants) |
|
|
| Siemens | SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) |
|
|
| Siemens | SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) |
|
|
| Siemens | SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) |
|
|
| Siemens | SIMATIC TDC CP51M1 |
|
|
| Siemens | SIMATIC TDC CPU555 |
|
|
| Siemens | SIMATIC WinAC RTX 2010 |
|
|
| Siemens | SIMATIC WinAC RTX F 2010 |
|
|
| Siemens | SIMOCODE pro V PROFINET (incl. SIPLUS variants) |
|
|
| Siemens | SIMOTION C |
|
|
| Siemens | SIMOTION D |
|
|
Vendors and products
- Siemens Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller
- Siemens Development/evaluation Kits For Profinet Io: Ek-ertec 200
- Siemens Development/evaluation Kits For Profinet Io: Ek-ertec 200p
- Siemens Siemens DK Standard Ethernet Controller Firmware
- Siemens Siemens EK-ERTEC 200P Firmware
- Siemens Siemens SIMATIC ET 200ALFirmware
- Siemens Simatic Et 200al Im 157-1 Pn
- Siemens Simatic Et200ecopn, 16di, Dc24v, 8xm12
- Siemens Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12
- Siemens Simatic Et200ecopn, 4ao U/i 4xm12
- Siemens Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12
- Siemens Simatic Et200ecopn, 8ai Rtd/tc 8xm12
Affected operating systems
| Other | siemens | dk_standard_ethernet_controller_firmware | — |
| Other | siemens | ek-ertec_200p_firmware | — |
| Other | siemens | ek-ertec_200pn_io_firmware | — |
| Other | siemens | simatic_compact_field_unit_firmware | — |
| Other | siemens | simatic_et_200al_firmware | — |
| Other | siemens | simatic_et_200ecopn_firmware | — |
| Other | siemens | simatic_et_200m_firmware | — |
| Other | siemens | simatic_et_200mp_firmware | — |
| Other | siemens | simatic_et_200pro_firmware | — |
| Other | siemens | simatic_et_200s_firmware | — |
| Other | siemens | simatic_et_200sp_firmware | — |
| Other | siemens | simatic_pn\/pn_coupler_firmware | — |
| Other | siemens | simatic_s7-1200_firmware | — |
| Other | siemens | simatic_s7-1500_controller_firmware | 2.0 |
| Other | siemens | simatic_s7-1500_firmware | — |
| Other | siemens | simatic_s7-200_firmware | — |
| Other | siemens | simatic_s7-300_firmware | — |
| Other | siemens | simatic_s7-400h_v6_firmware | — |
| Other | siemens | simatic_s7-400pn\/dp_v7_firmware | — |
| Other | siemens | simatic_s7-400pn_v6_firmware | — |
| Other | siemens | simatic_s7-410_v8_firmware | — |
| Other | siemens | simatic_winac_rtx_f_2010_firmware | — |
| Other | siemens | simocode_pro_v_profinet_firmware | — |
| Other | siemens | simotion_c_firmware | — |
Weakness classes (CWE)
CWE-400Uncontrolled Resource Consumption
Class
The product does not properly control the allocation and maintenance of a limited resource.
Entry at MITRE CWE-400
References & sources
- securityfocus.com101964Vulnerability database, x_refsource_BID
- Siemens ProductCERTproductcert/pdf/ssa-546832.pdfx_refsource_CONFIRM
- Siemens ProductCERTproductcert/pdf/ssa-346262.pdfx_refsource_CONFIRM
- Siemens ProductCERTproductcert/pdf/ssa-141614.pdfx_refsource_CONFIRM
- Siemens ProductCERTproductcert/html/ssa-346262.html
- Siemens ProductCERTproductcert/html/ssa-546832.html
- Siemens ProductCERTproductcert/html/ssa-141614.html
Embed badge
Show the severity and KEV status of this vulnerability on your site – with a link back here. The image is updated hourly.
<a href="https://intel.neosec.eu/en/cve/CVE-2017-12741"><img src="https://intel.neosec.eu/badge/cve/CVE-2017-12741.svg?lang=en" alt="CVE-2017-12741 – NEOSEC Intel" height="20"></a>