20
Vulnerabilities
0
Actively exploited (KEV)
0
Used by ransomware
8
Critical
Vulnerabilities
Actively exploited vulnerabilities (CISA KEV) first, then by priority. Click a column header to re-sort the table.
| Critical | CVE-2020-15782 | Siemens SIMATIC Drive Controller family: Improper Restriction of Operations within the Bounds of a Memory Buffer | 9.8 | |
| High | CVE-2021-37204 | Siemens SIMATIC Drive Controller family: Operation on a Resource after Expiration or Release | 7.5 | |
| High | CVE-2019-10936 | Siemens Development/Evaluation Kits for PROFINET IO: Uncontrolled Resource Consumption | 7.5 | |
| High | CVE-2019-19300 | Siemens Development/Evaluation Kits for PROFINET IO: Uncontrolled Resource Consumption | 7.5 | |
| Critical | CVE-2026-63350 | Siemens SIMATIC Drive Controller CPU 1504D TF: Eval Injection | 9.6 | |
| Critical | CVE-2026-63354 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 9.6 | |
| Critical | CVE-2026-63353 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 9.6 | |
| High | CVE-2019-6568 | Siemens SIMATIC CP 1604: Out-of-bounds Read | 7.5 | |
| Critical | CVE-2025-40943 | Siemens SIMATIC Drive Controller CPU 1504D TF: Eval Injection | 9.6 | |
| Critical | CVE-2026-25787 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 9.1 | |
| Critical | CVE-2026-25786 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 9.1 | |
| High | CVE-2019-10943 | Siemens SIMATIC: Missing Support for Integrity Check | 7.5 | |
| Medium | CVE-2026-63357 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 6.1 | |
| Medium | CVE-2026-63356 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 6.1 | |
| Medium | CVE-2026-63355 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 6.1 | |
| Medium | CVE-2026-63352 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 6.1 | |
| Medium | CVE-2026-63351 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 6.1 | |
| Medium | CVE-2019-10929 | Siemens SIMATIC CP 1626: Use of a Broken or Risky Cryptographic Algorithm | 5.9 | |
| High | CVE-2026-25789 | Siemens SIMATIC Drive Controller CPU 1504D TF: Cross-site Scripting | 7.1 | |
| Critical | CVE-2022-38465 | Siemens SIMATIC Drive Controller family: Insufficiently Protected Credentials | 9.3 |