Product by Compugroup Medical

    Venere

    11 known vulnerabilities in Venere (Compugroup Medical), 0 of them actively exploited (CISA KEV).

    Key figures

    11

    Vulnerabilities

    0

    Actively exploited (KEV)

    0

    Used by ransomware

    1

    Critical

    Vulnerabilities

    Actively exploited vulnerabilities (CISA KEV) first, then by priority. Click a column header to re-sort the table.

    Vulnerabilities in Venere (Compugroup Medical)
    CriticalCVE-2026-118462

    AIS update mechanism executes unverified code

    also in 3 other products

    —
    HighCVE-2026-118461

    AIS PersonnelService client performs unauthenticated doctor-specific operations

    also in 3 other products

    —
    HighCVE-2026-118458

    AIS shared test login provider contains fixed administrative credentials

    also in 1 other product

    —
    HighCVE-2026-118460

    AIS embedded private keys enable practitioner impersonation

    also in 3 other products

    —
    HighCVE-2026-118468

    AIS XML parsers allow external entity resolution

    also in 3 other products

    —
    MediumCVE-2026-118459

    AIS PasswordSOS permits authentication without legitimate credentials

    also in 3 other products

    —
    MediumCVE-2026-118795

    AIS stores authorization state in locally modifiable databases

    also in 2 other products

    —
    MediumCVE-2026-118450

    Venere loads replaceable unsigned components from a writable installation location

    —
    MediumCVE-2026-118465

    AIS products use vendor-wide hard-coded database credentials

    also in 3 other products

    —
    MediumCVE-2026-118464

    AIS shared cryptographic services use fixed cryptographic secrets

    also in 3 other products

    —
    MediumCVE-2026-118467

    AIS products expose clinical and personal data via logs and telemetry

    also in 3 other products

    —

    All products by Compugroup Medical